Building Alarms

Protect your investment and improve your return on benefit

Agri-Alert 800T (8 zones) & 2400 (24 zones) 

A complete alarm, dial-out and monitoring system with
8 programmable zones

Agri-Alert 800T

Protects your investment from the following most common causes of investment loss:

  • Power Failure
  • Fan Failure (High Temperature)
  • Faulty Heater (Low Temperature)
  • Failure in Control Equipment (Climate Controllers)
  • Failure in Feeding System (Feeder Motors, Feed Bin Motors)
  • Water Pressure
  • Burglar Alarm

8 Programmable Numbers:

  • Home
  • Cellular
  • Beeper 
  • Pagers
Outdoor Temperature Compensation
As the outside temperature approaches the high alarm setting, the setting is automatically adjusted higher so there is no need to manually adjust the high alarm on hot days.  This eliminates the common practice of raising the set point higher during hot days and having no active alarm.
Security:
  • Up to 10 programmable user access codes
  • Output for local siren or revolving light
  • Self-testing of complete system (fuses, battery, etc.)
  • Phone Line Seizure
  • 12 volt rechargeable battery backup
  • Memory is locked for all programmed parameters

 

  • ABS Enclosure:  Moisture and dust-tight for barn installations
System Flexibility:
  • Zone Configuration:  Dry contact, temperature
  • Easy bypass and activation of entire building through "Super Zones"
  • Built-In microphone for on-site listening
  • Programmable alarm recognition delays on individual zones
  • Transmission of alarm to pages, cellulars and telephones
  • Check both the temperature and technical functions of the entire system from an off-site telephone.

 

MAXIMUM SURGE PROTECTION
Maximum protection from surges which is the most common cause of alarm system failure.
Compared to most other alarm system, Agri-Alert 800T offers up to six time the protection.

SPECIAL "CAN'T IGNORE ALARM" FEATURE
If an alarm situation is acknowledged but not resolved within a given period of time, the system will launch another dial-out sequence.

Agri-Alert 800T - 8 programmable zones AGRAA800T $1085.45 Order Now
16.5 v Power Pack AGRPOWERPACK24 $ 135.15 Order Now
18" Sensor Probe AGRSENSORPROBE $ 15.09 Order Now

 

Agri-Alert 2400

A complete alarm, dial-out and monitoring system with
up to 24 programmable zones

Agri-Alert 2400

Protects your investment from the following most common causes of investment loss:

  • Power Failure
  • Fan Failure (High Temperature)
  • Faulty Heater (Low Temperature)
  • Failure in Control Equipment (Climate Controllers)
  • Failure in Feeding System (Feeder Motors, Feed Bin Motors)
  • Problems with the Water Supply

8 Programmable Numbers:

  • Home
  • Cellular
  • Beeper 
  • Numeric Pages
Outdoor Temperature Compensation
As the outside temperature approaches the high alarm setting, the setting is automatically adjusted higher so there is no need to manually adjust the high alarm on hot days.  This eliminates the common practice of shutting off the alarm during hot days and having no active alarm.
Security:
  • Up to 10 programmable user access codes
  • Output for local siren or revolving light
  • Self-testing of complete system (fuses, battery, etc.)
  • Phone Line Seizure
  • 12 volt rechargeable battery backup
  • Memory is locked for all programmed parameters

Protection:

  • Built in protection for power supply voltage surges and the telephone line
  • Built in protection on zone inputs against voltage surges.

Warranty

  • 2 years
System Flexibility:
  • Zone Configuration:  Dry contact, temperature, 0-5 V, 4-20 MA, Pulse Count
  • Easy bypass and activation of entire building through "Super Zones"
  • Built-In  or remote microphone for on-site listening
  • Programmable alarm recognition delays on individual zones
  • 2 outputs to take direct actions on the building from a remote location
  • Transmission of alarm to pages, cellulars and telephones

Durability

  • ABS Enclosure:  Moisture and dust-tight for barn installations

MAXIMUM SURGE PROTECTION
Maximum protection from surges which is the most common cause of alarm system failure.
Compared to most other alarm system, Agri-Alert 2400 offers up to six times the protection.

SPECIAL "CAN'T IGNORE ALARM" FEATURE
If an alarm situation is acknowledged but not resolved within a given period of time, the system will launch another dial-out sequence.

KEEP TRACK OF ALARM HISTORY
Alert 2400 Retains a record of sensors that went into alarm during the past armed period.  The last 10 alarms are kept in memory (can be viewed from keypad).

STATUS REPORTS ON EACH ZONE
Check both the temperature and technical functions of the entire system from a remote telephone.

Agri-Alert 2400 - 24 programmable zones AGRAA2400 $1275.00 Order Now
8 zone expansion card for 2400 AGREXPCARD $304.30 Order Now
16.5 v Power Pack AGRPOWERPACK24 $ 135.15 Order Now
18" Sensor Probe AGRSENSORPROBE $ 15.09 Order Now

 

Agri-Alert 9600

  • Grouping Zones:  Group all zones in a barn.  When the barn is empty all zones can be shutdown with one entry.
  • Only 4 wires between master, keypads and transponder
  • Simple installation
  • Reduces wiring costs in multiple barn or room installations

Configure zones for:

  • Pulse:  Water pressure
  • 0-5 Volt Sentor:  Pressure Gauge
  • 4-20 MA Sensor:  RPM
Event Memory
  • Records all system events such as alarms, arming, disarming, acknowledgements, dial outs, parameter adjustments etc... 
  • When the memory is full, the oldest events are deleted

Audio Message

  • Easy to identify the zone when calling the system on the phone.
  •  Know exactly where the alarms are coming from, and what it is.

Password 

  • One Master plus ten user passwords
  • Installer password
  • Records all in and outs of registered password holders:  what time they came in, what time they left.

Dial Out

  • Up to 16 phone numbers
  • Recall feature:  restarts the dial out sequence when an alarm has been acknowledged but not reset.

Line Seizure

  • Alert interrupted a phone conversation and begin Dial Out.
  • Prevents Dial out problems when a phone in to hung up properly

Monitoring Station

  • Can call you first, and then the monitoring station
  • No delay in getting the alarm while the monitoring station phones other clients
Local Siren
  • Save unnecessary dialouts:  most alarms occur when somebody is present.  A siren will give you enough time to locally acknowledge the alarm before the dial out begins.
  • Extra Protection:  Detect any malfunction of the telephone line. Automatically activate the siren.
  • Programmable Time Delay:  On siren activation

 

Test Program

  • Automatically tests complete system including fuses and battery. 
  • Memory record time of Test (Support insurance claims).

 

Sophisticated Lighting and Surge Protection

  • Gas tubes are used as a first protection
  • Varistor and Polywitch are used as second protection 
  • Filters are used as a third protection

 

Enclosure

  • Water and dust tight to cope with barn conditions.
  • Battery is in a separate Enclosure.  No danger of a leaking battery corroding the Master Control.
 

[Home]  
[Send Me Literature]    [Show Stopper Equipment]   [Farm Supplies Index]
  [Order Online - Shopping Cart]      [Clearance Items]

888-848-8373

Office Hours:  7:30 AM - 5:00 PM Central Time