Building Alarms
Protect your investment and improve your return on
benefit
Agri-Alert 800T (8 zones) & 2400 (24
zones)
A complete alarm, dial-out and monitoring system
with
8 programmable zones
|
 |
Agri-Alert 800T
Protects your investment from the following most common causes of
investment loss:
- Power Failure
- Fan Failure (High Temperature)
- Faulty Heater (Low Temperature)
- Failure in Control Equipment (Climate Controllers)
- Failure in Feeding System (Feeder Motors, Feed Bin Motors)
- Water Pressure
- Burglar Alarm
8 Programmable Numbers:
- Home
- Cellular
- Beeper
- Pagers
|
Outdoor Temperature
Compensation
As the outside temperature approaches the high alarm setting, the
setting is automatically adjusted higher so there is no need to manually
adjust the high alarm on hot days. This eliminates the common
practice of raising the set point higher during hot days and having no active
alarm. |
Security:
- Up to 10 programmable user access codes
- Output for local siren or revolving light
- Self-testing of complete system (fuses, battery, etc.)
- Phone Line Seizure
- 12 volt rechargeable battery backup
- Memory is locked for all programmed parameters
- ABS Enclosure: Moisture and dust-tight for barn installations
|
System Flexibility:
- Zone Configuration: Dry contact, temperature
- Easy bypass and activation of entire building through "Super
Zones"
- Built-In microphone for on-site listening
- Programmable alarm recognition delays on individual zones
- Transmission of alarm to pages, cellulars and telephones
- Check both the temperature and technical functions of the entire
system from an off-site telephone.
|
|
MAXIMUM SURGE PROTECTION
Maximum protection from surges which is the most common cause of
alarm system failure.
Compared to most other alarm system, Agri-Alert 800T offers up to six time
the protection.
SPECIAL "CAN'T IGNORE ALARM" FEATURE
If an alarm situation is acknowledged but not resolved within a given
period of time, the system will launch another dial-out sequence. |
|
Agri-Alert 800T - 8 programmable zones |
AGRAA800T |
$1085.45 |
Order
Now |
|
16.5 v Power Pack |
AGRPOWERPACK24 |
$ 135.15 |
Order
Now |
|
18" Sensor Probe |
AGRSENSORPROBE |
$ 15.09 |
Order
Now |
Agri-Alert 2400
A complete alarm, dial-out and monitoring system
with
up to 24 programmable zones
|
 |
Agri-Alert 2400
Protects your investment from the following most common causes of
investment loss:
- Power Failure
- Fan Failure (High Temperature)
- Faulty Heater (Low Temperature)
- Failure in Control Equipment (Climate Controllers)
- Failure in Feeding System (Feeder Motors, Feed Bin Motors)
- Problems with the Water Supply
8 Programmable Numbers:
- Home
- Cellular
- Beeper
- Numeric Pages
|
Outdoor Temperature
Compensation
As the outside temperature approaches the high alarm setting, the
setting is automatically adjusted higher so there is no need to manually
adjust the high alarm on hot days. This eliminates the common
practice of shutting off the alarm during hot days and having no active
alarm. |
Security:
- Up to 10 programmable user access codes
- Output for local siren or revolving light
- Self-testing of complete system (fuses, battery, etc.)
- Phone Line Seizure
- 12 volt rechargeable battery backup
- Memory is locked for all programmed parameters
Protection:
- Built in protection for power supply voltage surges and the
telephone line
- Built in protection on zone inputs against voltage surges.
Warranty
|
System Flexibility:
- Zone Configuration: Dry contact, temperature, 0-5 V, 4-20 MA,
Pulse Count
- Easy bypass and activation of entire building through "Super
Zones"
- Built-In or remote microphone for on-site listening
- Programmable alarm recognition delays on individual zones
- 2 outputs to take direct actions on the building from a remote
location
- Transmission of alarm to pages, cellulars and telephones
Durability
- ABS Enclosure: Moisture and dust-tight for barn installations
|
|
MAXIMUM SURGE PROTECTION
Maximum protection from surges which is the most common cause of
alarm system failure.
Compared to most other alarm system, Agri-Alert 2400 offers up to six
times the protection.
SPECIAL "CAN'T IGNORE ALARM" FEATURE
If an alarm situation is acknowledged but not resolved within a given
period of time, the system will launch another dial-out sequence.
KEEP TRACK OF ALARM HISTORY
Alert 2400 Retains a record of sensors that went into alarm during
the past armed period. The last 10 alarms are kept in memory (can be
viewed from keypad).
STATUS REPORTS ON EACH ZONE
Check both the temperature and technical functions of the entire
system from a remote telephone. |
|
Agri-Alert 2400 - 24 programmable zones |
AGRAA2400 |
$1275.00 |
Order
Now |
|
8 zone expansion card for 2400 |
AGREXPCARD |
$304.30 |
Order
Now |
|
16.5 v Power Pack |
AGRPOWERPACK24 |
$ 135.15 |
Order
Now |
|
18" Sensor Probe |
AGRSENSORPROBE |
$ 15.09 |
Order
Now |
Agri-Alert 9600
|
 |
- Grouping Zones: Group all zones in a barn. When the barn
is empty all zones can be shutdown with one entry.
- Only 4 wires between master, keypads and transponder
- Simple installation
- Reduces wiring costs in multiple barn or room installations
Configure zones for:
- Pulse: Water pressure
- 0-5 Volt Sentor: Pressure Gauge
- 4-20 MA Sensor: RPM
|
Event Memory
- Records all system events such as alarms, arming, disarming,
acknowledgements, dial outs, parameter adjustments etc...
- When the memory is full, the oldest events are deleted
Audio Message
- Easy to identify the zone when calling the system on the phone.
- Know exactly where the alarms are coming from, and what it is.
Password
- One Master plus ten user passwords
- Installer password
- Records all in and outs of registered password holders: what
time they came in, what time they left.
Dial Out
- Up to 16 phone numbers
- Recall feature: restarts the dial out sequence when an alarm
has been acknowledged but not reset.
Line Seizure
- Alert interrupted a phone conversation and begin Dial Out.
- Prevents Dial out problems when a phone in to hung up properly
Monitoring Station
- Can call you first, and then the monitoring station
- No delay in getting the alarm while the monitoring station phones
other clients
|
Local Siren
- Save unnecessary dialouts: most alarms occur when somebody is
present. A siren will give you enough time to locally
acknowledge the alarm before the dial out begins.
- Extra Protection: Detect any malfunction of the telephone
line. Automatically activate the siren.
- Programmable Time Delay: On siren activation
Test Program
- Automatically tests complete system including fuses and
battery.
- Memory record time of Test (Support insurance claims).
Sophisticated Lighting and Surge Protection
- Gas tubes are used as a first protection
- Varistor and Polywitch are used as second protection
- Filters are used as a third protection
Enclosure
- Water and dust tight to cope with barn conditions.
- Battery is in a separate Enclosure. No danger of a leaking
battery corroding the Master Control.
|
 |
 |
|